Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Upstairs Unit-Not Cooling Properly
Checked Unit. Found Unit Froze Up. Thawed Unit And Also Found A Bad Blower Capacitor, Replaced. Checked Unit Operation After Thawing Coil And Replace Capacitor. Found Unit One Pound Low Of Refrigerant. Set Charge. Unit Is Cooling Properly At This Time.
Also Installed (2) Customer Supplied Thermostats
Jefferson, GA
05-26-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-AC Not Cooling Properly
Found Unit Not Cooling Due To Dirty Filters, Replaced Customer Supplied Filters. Checked Charge And Found A Low Charge. Added Refrigerant And Monitored Unit.
Unit Is Cooling Properly
Jefferson, GA
05-06-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
4-7-2022-Completed Inspection
Checked All Capacitors ( All In Range), Electrical, Charge, Amps, Cleaned Coils (evap And Coil),installed New Drain Line, Checked Split.
Unit Is Operating Properly At This Time
Jefferson, GA
04-07-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Check Thermostat
Found New Thermostat Settings And Wiring Were Incorrect. Corrected Wiring And Settings And Tested To Ensure That The Unit Was Operating In Heating And Cooling Modes.
Jefferson, GA
04-01-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Heat Not Working Properly
Found Unit Not Heating Due To A Failing Blower Motor (constant Torque). Motor Is Failing On Speed Tap 2 And 3. Temporarily Moved The Fan To The Low Speed Tap And Tested Heat And Cooling. System Is Running At This Time But The Blower Motor Needs To Be Replaced. Replaced Dirty Filter And Removed The Dirty Filter From The Filter Grill In The Hall.
Will Quote To Replace The Blower Motor And Upsize A Return.
Jefferson, GA
03-03-2022




5 Star Rating
Air Conditioning Service, Repair And Installation Jefferson, GeorgiaCompleted (2) System Inspection
Inspected Both Main Level Systems Checking Electrical, Volts, Amps, Capacitors, Charges, Temperature Splits, Defrost, Heat Kits And Replaced Customer Provided Filters (2-16x20x1). Both Units Are Heating Properly At This Time.
JEFFERSON, GA02-03-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Unit Is Frozen.
Found Unit To Have Large Amounts Of Ice On The Condenser. Defrosted Unit And Checked Charge. Charge Looks Good And Unit Has A Good Split (41*F With Aux Heat Kit). Changed Defrost Time From 90 Min. To 30 Min.
Unit Is Heating Properly At This Time.
Jefferson, GA
01-26-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Furnace Wont Stop Running.
Found A Bad Control Board On Indoor Unit. Replaced Board And Monitored Unit Operation. Unit Is Heating Is Heating Properly At This Time.
Jefferson, GA
01-26-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Leak Check And Repair:
Pressure Tested And Leak Checked System And Found The Schrader Core On The Suction Line Leaking Badly. Replaced The Core And Leak Checked System. Found No Other Leaks At This Time With No Change In Pressure Test Over One Hour. Will Return On 1/13/22 To Charge.
Returned
Set Charge And Checked System Operation.
Unit Is Heating Properly At This Time.
Jefferson, GA
01-14-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
Clean Outdoor And Indoor Coil At Location.
Pumped Unit Down, Removed Evaporator Coil, Washed With Triple D. Reinstalled Coil, Leak Checked, Evacuated And Set Charge With 1 Pound Of R-410a.
Washed Condenser Coil With Pro-blue And Cleaned Debris Out Of Condenser. Unit Is Now Heat Properly At This Time.
Jefferson, GA
01-11-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
Arrived On Site. Checked All Duct Work, Duct Work Looks Good. Recommended Installing New Return Plenum And 5
Jefferson, GA
01-05-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Heat Not Working.
Found A Short In The Outdoor Unit Low Pressure Switch. Fixed Wiring And Monitored Unit Operation. Heat Is Working Properly At This Time.
Will Return And Install Customer Supplied Thermostat.
Installed Customer Supplied Thermostat
Jefferson, GA
01-05-2022
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Upstairs Unit Not Heating Properly.
Found A Bad Defrost Board. Will Return And Complete Repairs.
Returned-installed New Defrost Board. Unit Is Operating Properly At This Time.
Jefferson, GA
12-16-2021
Air Conditioning Service, Repair And Installation Jefferson, Georgia
Completed Winter Tune UP
Checked Unit. Added Clean Out And Cleared Drain Line. Filter Was Recently Replaced (1) 20x20x1 And Still Looks Good. Had A 30* Rise On The Heat Pump And A 60* Rise With Both Heat Pump And Auxiliary Heat Running. Checked Charge, Chare Is Good And Defrost Is Good As Well. Capacitors Are In Range, Need To Keep An Eye On The Dual Capacitor. It Is A Little Weak But Still In Normal Range.
System Is Heating Properly At This Time.
Jefferson, GA
12-10-2021
Air Conditioning Service, Repair And Installation Jefferson, Georgia
Main Level-Not Heating.
Checked System, Found A Dirty 20x20x1 Filter; Replaced. System Also Had A Blown Low-voltage Fuse; Replaced. Tested Defrost And System In Standard Heat And AC Mode With No Issues.
Unit Is Heating Properly At This Time.
Jefferson, GA
12-08-2021
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Check Nest Thermostat
Upstairs Thermostat-Found Low-voltage Fuse Blown. Replaced Fuse And Wired In Emergency Heat Wire On Thermostat. Replaced Filter.
Downstairs System-Wired In Emergency Heat Wire, Replaced Filter.
Units Are Operating Properly At This Time.
Jefferson, GA
11-22-2021
Air Conditioning Service, Repair And Installation Jefferson, Georgia
Installed A New Blower Motor. Checked Amp Draws And Motor Operation.
Unit Is Operating Properly At This Time.
Jefferson, GA
10-13-2021
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Unit Not Cooling Properly.
Checked System, Found System Has A Bad Constant Torque Motor. Will Quote To Replace.
Jefferson, GA
10-05-2021
Air Conditioning Service, Repair And Installation Jefferson, Georgia
-SVC-No A/C
Found Package Unit Not Cooling Due To Bad Hard Start Capacitor Causing Compressor Not To Start And Run. Replaced Hard Start Capacitor And Checked For Proper Operation.
Unit Is Cooling Properly At This Time.
Jefferson, GA
10-04-2021
Air Conditioning Service, Repair And Installation Jefferson, Georgia
SVC-Main Unit-Not Cooling Properly.
Found Secondary Pan Was Full Of Water And System Locked Out On Float Switch. Added Clean Out And Cleared Drain Line. Also Vacuumed All Of The Water Out Of The Secondary Pan. While On Site, Replaced Customer Supplied Filter (20x25x1).
Unit Is Cooling Properly At This Time.
Jefferson, GA
08-23-2021